Chapter 1. Setting Up the Hardware

This chapter describes how to set up the hardware for your system.

Deskside and Rackmount Systems

Your system was delivered with a deskside base unit or a rackmount base unit, as shown in the following figure.

Figure 1-1. Deskside and Rackmount Systems

Deskside and Rackmount Systems

The deskside base unit is designed for office environments. The base unit can sit beside a desk or on another sturdy surface close to the user. Access to the inside of the base unit is through the left side panel (as seen from the front of the system).

The rackmount base unit is designed for back-office environments such as server farms or equipment rooms. The base unit mounts in a standard 19-inch equipment rack in use at your site. Access to the inside of the base unit is through the top cover.

Unpacking the System


Warning: The base unit is heavy! To avoid personal injury or damage to equipment, use two persons to move the base unit.



Caution: Remove and move items carefully. Do not drop items on a hard surface, or damage to internal components may result. You may need help to move heavy items.

Remove everything from the shipping cartons and verify you have (at a minimum) these items:

  • System base unit and power cord

  • Rack-mounting hardware (rackmount system only)

  • Keyboard and mouse

  • Operating system software CD, diskettes, and documentation

  • Driver software CD

  • Monitor, power cord, and video cable (if purchased)

  • System documentation, including an Owner's Guide, a System Board Guide, and Release Notes (if provided)

Save the packaging materials. If you need to return equipment for repair, it must be in its original packaging for you to get warranty service.

Placing System Components

When placing system components, keep these guidelines in mind:

  • A deskside system should be placed on the floor or on a surface capable of supporting the full weight of the system.

  • A rackmount system should be mounted in a 19-inch equipment rack in use at your site.

  • Place the system in an area where air can circulate freely around it.

  • Do not expose the system to high levels of dust, smoke, or moisture.

  • Maintain a temperature range of 50 °F to 90 °F (10 °C to 32 °C); the optimum operating temperature is 70 °F (21 °C).

  • Maintain a humidity range of 20 percent to 80 percent non-condensing; the optimum humidity is 50 percent non-condensing.

Installing Rails for Rack Mounting

Your system was shipped with the base unit's top and side panels in place. If you purchased the optional rack mounting kit, you must remove the one-piece top-and-right-side panel (as seen from the front of the deskside base unit) before you can install rack-mount rails. To remove this panel, remove the screws that secure it to the back of the chassis, and then pull the panel back and away from the chassis.

Before Mounting a Rackmount System

Before mounting a system in an equipment rack in use at your site, prevent the rack from moving by engaging its stabilizers. If the rack is not equipped with stabilizers, refer to the rack documentation for stabilizing instructions.

Observe the following safety precautions when mounting the base unit in a rack in use at your site or when using the rackmount system:

  • Extend only one slide rail set at a time. Push an extended slide rail set back into the rack before extending another.


    Warning: Extending more than one slide rail set could cause the rack to fall forward, causing damage to equipment and injury to anyone in front of the rack.


  • Do not push on or lean against the rack. Always engage the stabilizers. The adjustable feet should be lowered securely against the floor.

  • If the rack contains an AC distribution box or an uninterruptible power supply (UPS), do not connect its the power cord to the wall outlet until instructed to do.

  • Set up the system completely before you start it.


    Warning: Do not move the rack with equipment mounted or powered on, or damage to internal components may occur. Shut down the system, unplug the system power cords from their AC power outlets, remove all equipment, and then move the rack.


Understanding Rackmount Vertical Units

A vertical unit (U) is an industry-standard measurement for rackmount equipment. Small markers on the rack mounting rails usually indicate each vertical unit. For more information, see the documentation for the racks in use at your site.

You should determine the vertical mounting space within a rack enclosure taken up by each device you want to install. For example, an AC distribution box may require 1U or 2U of mounting space, while the system's base unit requires 5U of mounting space.

Note the following about vertical units:

  • A vertical unit (U) equals 1.75 in (4.45 cm) and consists of three mounting holes.

  • The mounting hole diameter is 7.1 mm (industry standard).

  • Mounting holes are counted upward after locating the first mounting hole within the range of vertical units required to install the equipment.

The following figure shows the typical installation of a tinnerman nut to mounting hole 3 of a vertical unit.

Figure 1-2. Tinnerman Nut Installation

Tinnerman Nut Installation

Mounting the Base Unit in a Rack

The following procedure describes how to mount a rackmount system's base unit in a typical 19-inch equipment rack. For detailed information on mounting equipment in a rack, see the documentation for the equipment racks in use at your site.


Warning: The base unit is heavy! To avoid personal injury or damage to equipment, use two persons to mount the base unit in an equipment rack.

To mount the base unit in an equipment rack:

  1. Remove the screws securing each side of the front panel to the base unit. Holding each handle bracket in place, replace the screws through each bracket and the front panel into the base unit.

    Figure 1-3. Handle Bracket

    Handle Bracket

  2. Remove the guide from each of the two rails. The guide is the innermost-sliding piece of the rails, and has a flexible tab at one end.

  3. Attach a guide to each side of the base unit using the flat-head screws provided, making sure the flexible tab on the guide is toward the back of the base unit. Align each guide with the lower set of three screw holes in each side of the base unit.

    Figure 1-4. Rail Guide

    Rail Guide

  4. Use the button-head screws and bolts provided to loosely secure a bracket to each rail. The bracket has the teeth needed to secure the rail to the equipment rack. Install the button-head screws and bolts loosely so you can adjust the back teeth positions later.

    Figure 1-5. Bracket on Rail

    Bracket on Rail

  5. The rackmount base unit requires 6U (10.5 in or 26.7 cm) of mounting space. Choose the five vertical units you need and, on the equipment rack mounting rails, mark the fifth and sixth mounting holes from the bottom of this 6U space.

  6. Use the flat-head screws and bar nuts to secure the front teeth on both rails to the front mounting rails of the equipment rack.

    With the flat side of each bar nut facing the screws, loosely install two flat-head screws to each bar nut, through the fifth and sixth mounting holes from the bottom of the 6U space. Slide the front teeth over the screws and tighten. Ensure the front teeth are between the bar nuts and the mounting holes.

    Figure 1-6. Rail Secured to Front Mounting Rail on Equipment Rack

    Rail Secured to Front Mounting Rail on Equipment Rack

  7. On the front mounting rails on the equipment rack, slide tinnerman nuts over the third and thirteenth mounting holes from the bottom of the 6U space. The tinnerman nuts will be used when you secure the handle brackets on the front of the base unit to the front mounting rails of the equipment rack.

    Figure 1-7. Installing the Tinnerman Nuts

    Installing the Tinnerman Nuts

  8. Use the button-head screws and bar nuts provided to secure the back rail teeth to the back mounting rails of the equipment rack.

    With the flat side of each bar nut facing the screws, loosely install two button-head screws to the bar nut, through the fifth and sixth mounting holes from the bottom of the 6U space. Slide the back teeth over the screws and tighten. Ensure the back teeth are between the bar nuts and the mounting holes.

    Figure 1-8. Rail Secured to Rear Mounting Rail on Equipment Rack

    Rail Secured to Rear Mounting Rail on Equipment Rack

  9. At the back of the equipment rack, tighten the screws and bolts on the brackets of each rail.

  10. Extend the rails from the equipment rack until they lock.

  11. With a person on each side, lift the base unit and align the rails with the guides attached to the sides of the base unit. Slide the base unit into the rails until you hear a click.

  12. Press the locked rail tabs and slide the base unit completely back into the equipment rack. After the base unit slides back a few inches, the base unit and rails slide together as a unit into the equipment rack. See Figure 1-9.

    Figure 1-9. Rail on Rail Guide

    Rail on Rail Guide

  13. Install the black screws through the handle brackets and the tinnerman nuts you installed previously to secure the base unit to the front mounting rails of the equipment rack.

Connecting System Components


Caution: If you do not use the cables delivered with the system, use shielded cables to prevent excessive electromagnetic interference (EMI). The cables delivered with the system reduce the amount of EMI produced by the system.



Note: You should disconnect the cables from the base unit before extending it from the rack, but if needed, you can extend the base unit without disconnecting the cables. Be sure there is enough cable to allow the base unit to fully extend from the rack. Use caution not to pinch the cables while extending or retracting the base unit.

After placing the system components, connect them together using the included cables. The base unit and other system components have keyed and labeled ports, to make it easier to connect them together with the right cables. If you cannot connect a cable easily, ensure that you are aligning the cable connector correctly with the port.

Figure 1-10 and Figure 1-11 illustrate the back of the base unit. Most ports on the back of the base unit are colored and labeled with icons for easy reference. Locations of expansion cards and their ports may differ from those shown.


Note: On a deskside system, the SCSI port is at the top and the expansion ports are at the bottom (as seen when facing the back of the base unit).

Figure 1-10. The Back of the Base Unit

The Back of the Base Unit

Figure 1-11. The I/O Panel

The I/O Panel

To connect the system components:

  1. Connect a video cable from the monitor to the video out port on the graphics controller card. See the graphics controller documentation for more information.

  2. Connect cables from the keyboard and the mouse to their ports.

  3. Connect a cable from your site's Ethernet network to the Ethernet port.

  4. Connect a cable from a parallel peripheral device to the parallel port.

  5. Connect cables from any serial peripheral devices to the serial ports.

  6. Connect cables from any USB peripheral devices to the USB ports.

  7. Connect the cable from any external SCSI peripheral devices, or a SCSI terminator module, to the SCSI port. See “ More Information” in this chapter.


    Caution: If you do not connect an external SCSI peripheral device to the SCSI port, connect a terminator module to the port.


  8. Connect cables to ports on any other installed expansion cards as required. See the expansion card documentation for more information.

  9. Install removable disk drives in the disk drive cage. See “ Getting Support” in this chapter for more information.


    Caution: Do not connect the system power cord to the base unit or to an AC power outlet at this time. See “Connecting to AC Power” later in this chapter for more information.


Locating Expansion Cards

Expansion cards are installed as needed in the Accelerated Graphics Port (AGP), Peripheral Component Interconnect (PCI), and Industry Standard Architecture (ISA) expansion slots.

Figure 1-12. Expansion Slots

Expansion Slots


Caution: The following table describes the expansion slots and any typically installed expansion cards. Note that Slot 7 is a shared PCI/ISA slot; you can install a PCI expansion card or an ISA expansion card in this slot, but not both.


Table 1-1. Expansion Slots and Cards

Slot

Type

Typical Expansion Cards Installed

1 (Left or top)

AGP

Graphics controller

2

PCI (64-bit/33 MHz)

Varies by system

3

PCI (64-bit/33 MHz)

RAID controller

4

PCI (64-bit/33 MHz)

Varies by system

5

PCI (64-bit/66 MHz)

Varies by system

6

PCI (64-bit/66 MHz)

Varies by system

7

PCI (64-bit/33 MHz)

Varies by system

7 (Right or bottom)

ISA

Varies by system



Caution: If a modem card used in the system receives ground from the system, ensure the system is connected to an earth-grounded AC power outlet.

For information on installing or connecting to expansion cards, see Chapter 8, “Upgrading the System” and the expansion card documentation delivered with the system.

Installing Removable RAID Disk Drives

In a RAID system, the base unit's disk drive cage may contain up to four removable low-voltage differential (LVD) SCSI disk drives. An installed RAID controller card manages these disk drives and provides RAID capabilities to the system.

These SCSI disk drives can be accessed through a door on the front panel. On a rackmount system, the door is to the right (as seen when facing the front of the system). On a deskside system, the disk drive cage door is at the bottom (as seen when facing the front of the system). A key (delivered with the system) locks and unlocks the disk drive door.

Figure 1-13. Removable RAID Disk Drive Cage, Door Closed

Removable RAID Disk Drive Cage, Door Closed

Figure 1-14. Interior of Disk Drive Cage

Interior of Disk Drive Cage

Each SCSI disk drive installed in the disk drive cage has a label affixed to the front. The left side of the disk drive label identifies the disk drive size (in GB). The label has blank spaces for the numbers to indicate the adapter (ADP), the channel (CH), and the identification number (ID). Standard disk drives include values for the adapter, channel, and identification number filled in. Additional disk drives have a blank label (supplied) that you must complete after installation.

Figure 1-15. SCSI Disk Drive Labels

SCSI Disk Drive Labels

To install removable drives:

  1. Open the disk drive cage door on the front of the base unit.

  2. Carefully remove the disk drives from their carton and place them on an antistatic surface. Open the antistatic bags and remove the disk drives. Note the ID number on the disk drives.

  3. Extend the latch clips on Drive 0 and align the upper and lower edges of the disk drive's mounting plate with the disk drive rails at the right end or top end of the disk drive cage. For a rackmount system, the mounting plate faces to the right; for a deskside system, the mounting plate faces up.

  4. Push the disk drive at the center between the latch clips until it slides all the way onto the rails and firmly engages its connector. The latch clips rotate closed as you push the disk drive onto the rails.

  5. Repeat steps 3 and 4 to install each remaining disk drive, moving to the left or down as you install each new disk drive. Do not leave empty rails between disk drives.

Connecting External SCSI Devices

The system has a dual-channel low-voltage differential (LVD) SCSI controller integrated on the system board. You can connect external Ultra, Ultra2, or Ultra3 SCSI devices to this controller through the SCSI port on the back of the base unit.

Figure 1-16. SCSI Port

SCSI Port


Caution: On a RAID system, do not connect external SCSI peripheral devices to the non-functional SCSI port on the RAID controller card.



Caution: On a JBOD system, if you do not connect an external SCSI peripheral device to the SCSI port, connect a terminator module to the port.



Note: On a deskside system, the SCSI port is at the top when facing the back of the base unit.


To ensure data integrity and promote optimum performance:

  • Use the shortest cables possible to connect SCSI peripheral devices.

  • Use high-quality SCSI cables to ensure adequate shielding (impedance of 110 to 135 ohms).

To connect external SCSI devices:

  1. If the system is connected to AC power and operating, shut down the system and unplug the system power cord from its AC power outlet.

  2. If a terminator module is connected to the SCSI port on the system, remove it.

  3. Connect one end of a SCSI cable to the SCSI port on the system.

  4. Connect the other end of the SCSI cable to a SCSI peripheral device.

  5. Connect a SCSI cable between SCSI ports on any additional SCSI peripheral devices.

  6. Set the SCSI ID of each peripheral device to a unique SCSI ID number. Do not use any SCSI ID numbers already used by the system.

  7. For each SCSI peripheral device connected to the port, if the device is:

    • The last or only device on the SCSI chain, install or enable SCSI termination

    • Not the last or only device on the SCSI chain, disable or remove SCSI termination

  8. Ensure that the power switch on each peripheral device is in the off position; then connect the power cord from each peripheral device to an AC power outlet.

  9. Turn on power to all connected SCSI peripheral devices, and then start the system.

  10. If necessary, install software drivers and configure the peripheral devices according to the vendor's instructions.

See Chapter 8, “Upgrading the System” for additional details on installing external SCSI peripheral devices.

Connecting to AC Power


Caution: The power switches on the unit's two power supplies are the service diconnect. To remove AC power from the system, you must turn the power switch on both power supplies to the off (o) position.



Caution: Ensure the AC power outlet to which the system's power cords connect are close to the system and are easily accessible.

The system has two power supplies. Both must be connected to AC power for the system to operate correctly. However, if one power supply fails, you can replace it without shutting down the other power supply. This hot-swap capability lets you handle a power supply failure without shutting down and powering down the entire system.

When you connect the system's base unit to AC power and turn the Power switches on both power supplies to the on ( | ) position, auxiliary power is applied to the system. Auxiliary power ensures that system components power up quickly when needed. See Chapter 4, “Operating the System” for more information on controlling system power.

Figure 1-17. Power Supplies

Power Supplies

To connect the system to AC power:

  1. Make sure the AC voltage selection switches on both power supplies (on the back of the base unit) are set to the proper line voltage for your location.

    • If your location uses 90 to 135 volts, the number 115 must be visible.

    • If your location uses 180 to 264 volts, the number 230 must be visible.


      Warning: If you do not set the AC voltage selection switches on the power supplies correctly, equipment damage may occur when you connect the system to AC power.


  2. Make sure the Power switches on both power supplies are set to the off ( O ) position.

  3. Connect the system's power cords to the AC power receptacles on both power supplies.

  4. Connect the power cords from the monitor, base unit, and any external peripheral devices to properly grounded three-prong AC power outlets.

  5. Turn the Power switches on both power supplies to the on ( | ) position. This applies auxiliary power to the system. The power supply light-emitting diodes (LEDs) light when the power supplies are operating.

Starting the System


Caution: If you start the system, and then turn it off before completing the instructions in Chapter 2, “Setting Up the Software” you will have to reinstall the operating system and associated system software. See “ Getting Support” for more information.



Caution: Before starting the system for the first time, you may want to learn more about system power, startup, and shutdown. See Chapter 4, “Operating the System” for more information.

To start (apply full power to) the system, turn the Power keyswitch shown in the following figure to the right (clockwise), and then release it.

Figure 1-18. System Power Keyswitch

System Power Keyswitch

If your system does not have a Power keyswitch on the front panel, you will find Power and Reset buttons behind the door on the front panel, above the disk drives. To start (apply full power to) the system, press the Power switch momentarily and then release it.

What's Next?

You can do the following to prepare your system for use:

  • If you want to get going with the default setup, go to Chapter 2, “Setting Up the Software” to start the system and go through operating system Setup. If you start the system and then turn it off before completing operating system Setup, you will have to reinstall the operating system and associated system software.

  • The operating system is already installed through the first phase of the Setup process. If you want to reload the operating system and associated system software instead of completing Setup, see Chapter 6, “Reinstalling the Operating System”.

  • On a RAID system, the default RAID setup is disk drives striped to RAID level 5, with a write-through write policy. The default setup is described in more detail in Chapter 3, “Configuring the System”.

Silicon Graphics Zx10 6U Rackmount Owner's Guide
(document number: 007-4329-002 / published: 2000-09-20)    table of contents  |  additional info  |  download

    Front Matter
    About This Guide
    Chapter 1. Setting Up the Hardware
    Chapter 2. Setting Up the Software
    Chapter 3. Configuring the System
    Chapter 4. Operating the System
    Chapter 5. Troubleshooting Operational Problems
    Chapter 6. Reinstalling the Operating System
    Chapter 7. Gaining Access to System Components
    Chapter 8. Upgrading the System
    Chapter 9. Servicing the System
    Chapter 10. System Hardware and Specifications
    Appendix A. Ergonomics Guide
    Index


home/search | what's new | help