IRIX 6.5 » Books » Administrative »
Origin FibreVault and Fibre Channel RAID Administrator's Guide
(document number: 007-3715-002 / published: 1998-12-23)
table of contents | additional info | download find in page
- agent
- fcagent
- The Agent fcagent
- starting and stopping
- The Agent fcagent
- version
- Determining the fcagent Version Number
- ssmagent
- Checking ssmagent Installation
- restarting
- Restarting ssmagent
- See also ssmagent.
- Checking ssmagent Installation
- version
- getagent
- architecture
- ssmgui Architecture
- array
- component
- information
- Getting Information on Other Array Components
- missing
- Checking a Faulted Array
- configuration overview
- Array Configuration and Management
- fault
- checking
- Checking a Faulted Array
- icon
- Enclosure Health and Accessibility
- information
- Array Status Button
- icon
- Interpreting Array Icons
- Array Icons in the Array Selection Area
- fault
- Array Health Indicators in the Storage System Manager Window
- inaccessible
- Enclosure Health and Accessibility
- information
- Using the Array Information Window
- managing
- Using the Array Selection Filter (Managing and Unmanaging Arrays)
- memory, setting up
- Setting Up Array Memory
- more than one server
- Icons Connected to More Than One Server
- name
- Array Name
- reestablishing communication
- Re-Establishing Communication With an Array
- selecting
- Selecting an Array
- selection
- area
- Storage System Manager Window
- Storage System Manager Window
- Storage System Manager Window
- filter
- Storage System Manager Window
- Storage System Manager Window
- filter:using
- Using the Array Selection Filter (Managing and Unmanaging Arrays)
- status button
- Array Health Indicators in the Storage System Manager Window
- Storage System Manager Window
- Array Status Button
- Storage System Manager Window
- toolbar
- Storage System Manager Window
- Using Array Toolbar Buttons
- unmanaged
- Using the Array Selection Filter (Managing and Unmanaging Arrays)
- restoring to managed
- Using the Array Selection Filter (Managing and Unmanaging Arrays)
- unsupported
- Enclosure Health and Accessibility
- upgrading
- for caching
- Upgrading an Array for Caching
- with higher capacity disk modules
- Upgrading an Array With Higher Capacity Disk Modules
- Array Configuration window
- disk module information
- Getting LUN and Disk Information in the Array Configuration Window
- features
- Using the Array Configuration Window to Set Up the Array
- LUN information
- Getting LUN and Disk Information in the Array Configuration Window
- toolbar
- Using Array Toolbar Buttons
- Array Information window
- Using the Array Information Window
- auto assign
- Bind Parameters
- Bind Parameters
- Bind Parameters
- chglun
- changing
- Changing LUN Parameters in the Array Configuration Window
- RAID 3
- Setting Bind Parameters: RAID 3 and Hot Spares
- setting
- Setting Bind Parameters: RAID 5, 1, 1/0, or 0
- state
- getlun
- Auto Poll indicator
- Auto Poll Indicator
- Array Health Indicators in the Storage System Manager Window
- Storage System Manager Window
- Storage System Manager Window
- back-end memory
- Memory and Caching
- getcache
- background verification
- getsniffer
- ssmgui Architecture
- setsniffer
- setting
- setsniffer
- setspstime
- bind
- bind
- and number of LCCs
- Recovering From an Incorrect Bind
- defaults
- Bind Parameters
- order
- LUN Binding Order and Restrictions
- planning
- Planning the Bind
- setting parameters
- RAID 3, hot spare
- Setting Bind Parameters: RAID 3 and Hot Spares
- RAID 5, 1, 1/0, 0
- Setting Bind Parameters: RAID 5, 1, 1/0, or 0
- stopping
- Recovering From an Incorrect Bind
- Setting Bind Parameters: RAID 3 and Hot Spares
- Setting Bind Parameters: RAID 5, 1, 1/0, or 0
- time required
- Setting Bind Parameters: RAID 5, 1, 1/0, or 0
- Setting Bind Parameters: RAID 3 and Hot Spares
- Bind LUNs dialog
- Setting Bind Parameters: RAID 5, 1, 1/0, or 0
- cable length
- Origin2000 and Onyx2 Serial Pinout
- caching
- getcache
- setcache
- Enhanced Performance: Storage System Caching
- and memory partitioning
- Memory and Caching
- disabling
- bind Syntax
- Enabling or Disabling Array Caching
- enabling
- bind Syntax
- Enabling or Disabling Array Caching
- hardware requirements
- Upgrading an Array for Caching
- Hardware Requirements for Caching: LUNs Other than RAID 3
- LUN information window
- LUN Cache Information
- optimizing
- Using Storage System Statistics for Cache Optimizing
- page
- getcache
- page size
- Cache and Cache Page Size
- Cache and Cache Page Size
- changing
- setcache
- Changing Cache Page Size
- parameters, changing
- Changing Caching Parameters
- read-ahead. See prefetch.
- Changing Prefetch (Read-Ahead Caching) Parameters
- replacing disk module
- Replacing a Database or Cache Vault Disk Module
- SP information window
- SP Cache Information
- state
- getcontrol
- watermarks, changing
- setcache
- Changing Write Cache Watermarks
- chglun
- chglun
- clearlog
- clearlog
- clearstats
- clearstats
- command-tagged queuing
- Enabling Command-Tagged Queuing
- Components For Array window
- Getting Information on Other Array Components
- configuration file
- ssmagent Users and Sessions
- conventions
- Conventions
- Conventions
- CRU
- Checking a Faulted Array
- getcrus
- .cshrc
- Configuring the Path to ssm Executables in .cshrc
- CTQ. See command-tagged queuing.
- Enabling Command-Tagged Queuing
- data
- rebuilding
- Data Reconstruction and Rebuilding After Disk Module Failure
- reconstruction
- LUN Integrity and Disk Module Failure
- Data Reconstruction and Rebuilding After Disk Module Failure
- redundancy
- Data Redundancy
- Data Reconstruction and Rebuilding After Disk Module Failure
- LUN Integrity and Disk Module Failure
- RAID 3
- RAID 3: Parallel Access Array
- RAID 5
- RAID 5: Individual Access Array
- disk field
- Disk Field
- disk module
- 00, 01, 02
- Upgrading an Array With Higher Capacity Disk Modules
- moving
- Moving Disk Modules
- See also disk module, database.
- Upgrading an Array With Higher Capacity Disk Modules
- cache vault, replacing
- Replacing a Database or Cache Vault Disk Module
- Configuration information window
- Using the Disk Information Windows
- database
- Upgrading an Array With Higher Capacity Disk Modules
- replacing
- Replacing a Database or Cache Vault Disk Module
- See also disk module, 00, 01, 02.
- Upgrading an Array With Higher Capacity Disk Modules
- Error information window
- Disk Module Error Information
- failure, and LUN integrity
- LUN Integrity and Disk Module Failure
- fault
- Faulted Disk Module
- higher capacity
- Upgrading an Array With Higher Capacity Disk Modules
- icon color
- LUN and Disk Module Icon Color
- ID
- Disk Module IDs
- information
- Getting LUN and Disk Information in the Array Configuration Window
- getdisk
- Using the Disk Information Windows
- JBOD
- bypassing
- Bypassing a JBOD Drive
- check LEDs on and off
- Turning Disk Check LEDs On or Off
- replacement, bringing up
- Bringing Up a Replacement Drive
- taking offline
- Taking JBOD Drives Offline
- unbypassing
- Bringing JBOD Drives Back Online (Unbypassing)
- LED, flash to locate
- Checking a Faulted Array
- LIC
- Upgrading an Array With Higher Capacity Disk Modules
- RAID Types
- locating
- Checking a Faulted Array
- moving
- Moving Disk Modules
- replacing
- Replacing a Disk Module
- Statistics information window
- Disk Module Statistics Information
- taking offline
- Disk Module Failure and Powering Off, Unbinding, or Taking Disks Offline
- types
- Fibre Channel Disk Module Types
- disk striping. See striping.
- Enhanced Performance: Disk Striping
- documents, other
- Other Documentation
- environmental variables
- Environment Variables RaidAgentHost, RaidAgentDevice, and RaidAgentTimeout
- Equipment View window
- Getting Information on Other Array Components
- Checking a Faulted Array
- error
- Disk Module Error Information
- code
- explanations
- Displaying an SP Event Log
- series
- Displaying an SP Event Log
- disk module, information
- Disk Module Error Information
- information
- Array Status Button
- log. See event log.
- Displaying an SP Event Log
- messages. See event log.
- Displaying an SP Event Log
- values for ssmcli
- ssmcli Error Values
- event
- log
- Displaying an SP Event Log
- monitor
- ssmgui Architecture
- Using the Event Monitor
- extended memory
- Partitioning Array Memory
- Partitioning Array Memory
- external Fibre Channel Hub
- Checking a Faulted Array
- getcrus
- Enclosure Health and Accessibility
- failback
- failback
- failover
- Transferring Control of a LUN (Manual Trespass)
- fan fault, fan pack fault
- getcrus
- fan fault, fan pack fault
- Faulted Fan
- faulted array icon
- Enclosure Health and Accessibility
- fcagent. See agent.
- The Agent fcagent
- fccli
- The Fibre Channel Non-RAID Command-Line Interface
- Fibre Channel Hub
- Enclosure Health and Accessibility
- getcrus
- Checking a Faulted Array
- flushing
- getcontrol
- front-end memory
- Memory and Caching
- getcache
- fx
- Enabling Command-Tagged Queuing
- getagent
- getagent
- getcache
- getcache
- getcontrol
- getcontrol
- getcrus
- getcrus
- getdisk
- getdisk
- getlog
- getlog
- getloop
- getloop
- getlun
- getlun
- getsniffer
- getsniffer
- hardware graph
- Getting a Fibre Channel Hardware Graph Output
- hinv
- Listing Fibre Channel Controller and Drive Numbers
- Host Administration window
- Using the Host Administration Window to Add Servers
- hostname
- adding
- Using the Host Administration Window to Add Servers
- removing
- Removing Servers
- hot spare
- RAID Hot Spare
- and inaccessible LUN
- LUN Integrity and Disk Module Failure
- and RAID 3
- LUN Binding Order and Restrictions
- Planning the Bind
- limit
- Setting Bind Parameters: RAID 3 and Hot Spares
- LUN number, setting
- Setting Bind Parameters: RAID 3 and Hot Spares
- mixed mode
- Bandwidth Mode and Mixed Mode
- RAID 0
- RAID Hot Spare
- RAID 3
- RAID Hot Spare
- LUN Integrity and Disk Module Failure
- restrictions
- LUN Binding Order and Restrictions
- Planning the Bind
- icon
- array
- Array Icons in the Array Selection Area
- array components
- Getting Information on Other Array Components
- color
- Enclosure Health and Accessibility
- disk module
- LUN and Disk Module Icon Color
- LUN
- LUN and Disk Module Icon Color
- Storage System Manager
- Array Health Indicators in the Storage System Manager Window
- idle
- count
- Changing Prefetch (Read-Ahead Caching) Parameters
- threshold
- chglun
- getlun
- time
- getcontrol
- chglun
- getlun
- inaccessible
- array
- Enclosure Health and Accessibility
- LUN
- LUN Integrity and Disk Module Failure
- individual disk unit
- Individual Disk Unit
- ioconfig
- Making LUNs Available to the Server Operating System
- Transferring Control of a LUN (Manual Trespass)
- IRIX
- utilities for JBOD information
- Using IRIX Utilities to Get JBOD Information
- version required
- About This Guide
- JBOD
- disk module. See disk module, JBOD.
- Taking JBOD Drives Offline
- software
- The Fibre Channel Non-RAID Command-Line Interface
- status
- Getting Channel and Enclosure Status
- user interface
- The Fibre Channel Non-RAID Command-Line Interface
- LCC
- and bind
- Recovering From an Incorrect Bind
- fault
- Faulted LCC
- state
- getcrus
- LIC
- disk modules
- Upgrading an Array With Higher Capacity Disk Modules
- memory requirement
- Partitioning Array Memory
- Memory and Caching
- Partitioning Array Memory
- and user free memory
- Memory Partitioning Points
- logical unit number
- Fibre Channel RAID Graphical User Interface Features
- See also LUN.
- Fibre Channel RAID Graphical User Interface Features
- LUN
- Fibre Channel RAID Graphical User Interface Features
- bind
- Binding Disk Modules
- buttons
- Binding Disk Modules
- Cache information window
- LUN Cache Information
- Configuration information window
- Using the LUN Information Windows
- disk module ownership
- LUN Ownership of Disk Modules
- fault
- Faulted LUN
- icon
- LUN Icons and IDs
- color
- LUN and Disk Module Icon Color
- ID
- LUN Icons and IDs
- setting
- Setting Bind Parameters: RAID 5, 1, 1/0, or 0
- information
- Getting LUN and Disk Information in the Array Configuration Window
- Using the LUN Information Windows
- integrity and disk module failure
- LUN Integrity and Disk Module Failure
- making available to OS
- Making LUNs Available to the Server Operating System
- number
- hot spare
- Setting Bind Parameters: RAID 3 and Hot Spares
- number
- Bind Parameters
- RAID type, changing
- Changing LUN RAID Type
- rebuilding
- Rebuilding a RAID 5, 3, 1, or 1/0 LUN
- Statistics information window
- LUN Statistics Information
- toolbar
- Reconfiguring and Fine-Tuning
- transferring control
- Transferring Control of a LUN (Manual Trespass)
- unbind
- Unbinding a LUN
- unowned
- LUN Integrity and Disk Module Failure
- manual trespass
- Transferring Control of a LUN (Manual Trespass)
- memory
- back-end
- getcache
- Memory and Caching
- front-end
- Memory and Caching
- getcache
- RAID 3
- Memory, Bandwidth Mode, and Mixed Mode
- read cache
- Memory, Bandwidth Mode, and Mixed Mode
- setting up partitions
- Memory Partitioning Points
- write cache
- Memory, Bandwidth Mode, and Mixed Mode
- Memory Partition window
- Partitioning Array Memory
- minibind
- Upgrading an Array With Higher Capacity Disk Modules
- minimal latency reads
- Bind Parameters
- chglun
- Bind Parameters
- bind Syntax
- changing
- Changing LUN Parameters in the Array Configuration Window
- setting
- Setting Bind Parameters: RAID 3 and Hot Spares
- state
- getlun
- mixed mode
- Bandwidth Mode and Mixed Mode
- setraid5
- RAID 3
- Setting Bind Parameters: RAID 3 and Hot Spares
- Setting Bind Parameters: RAID 3 and Hot Spares
- setraid5
- page size
- and memory allocation
- Memory Partitioning Points
- changing
- setcache
- Changing Cache Page Size
- parity data
- RAID 5: Individual Access Array
- Data Reconstruction and Rebuilding After Disk Module Failure
- partitioning memory
- Memory Partitioning Points
- performance
- and command-tagged queuing
- Enabling Command-Tagged Queuing
- LUN, and cache optimizing
- getcache
- Using Storage System Statistics for Cache Optimizing
- Identifying and Correcting Failures
- getcache
- pinouts, serial
- Server Serial Connector Pinouts
- OCTANE
- OCTANE Serial Pinouts
- Origin200
- Origin200 Serial Pinouts
- Origin2000 and Onyx2
- Origin2000 and Onyx2 Serial Pinout
- polling
- Using ssmagent Polling
- array
- Using the Array Information Window
- Auto Poll indicator
- Array Health Indicators in the Storage System Manager Window
- Auto Poll Indicator
- automatic
- Automatic Polling
- disabling, enabling
- Disabling and Enabling Automatic Polling
- interval
- ssmagent Polling Interval and Polling Requests
- changing
- Changing the Polling Interval
- requests
- ssmagent Polling Interval and Polling Requests
- power supply
- fault
- Faulted Power Supply
- state
- getcrus
- prefetch parameters
- chglun
- getlun
- changing
- Changing Prefetch (Read-Ahead Caching) Parameters
- r3wrbuff
- r3wrbuff
- RAID
- CLI
- The Fibre Channel RAID Command-Line Interface
- ssmgui Architecture
- GUI
- ssmgui Architecture
- and ssmagent
- Starting the RAID GUI
- exiting
- Exiting a RAID GUI Session
- See also ssmgui.
- Starting the RAID GUI
- starting
- Starting the RAID GUI
- number of disk modules per type
- Planning the Bind
- LUN Binding Order and Restrictions
- rebuilding
- Rebuilding a RAID 5, 3, 1, or 1/0 LUN
- type 0
- RAID 0 Group: Nonredundant Array
- hot spare
- RAID Hot Spare
- mixed mode
- Bandwidth Mode and Mixed Mode
- setraid5
- number of disk modules
- LUN Binding Order and Restrictions
- Planning the Bind
- LUN Binding Order and Restrictions
- Planning the Bind
- rebuilding
- Rebuilding a RAID 0 LUN
- striping
- RAID 0 Group: Nonredundant Array
- type 1
- RAID 1: Mirrored Pair
- mixed mode
- setraid5
- Bandwidth Mode and Mixed Mode
- rebuilding
- Rebuilding a RAID 5, 3, 1, or 1/0 LUN
- type 1/0
- RAID 1/0 Group: Mirrored RAID 0 Group
- disk module selection order
- Setting Bind Parameters: RAID 5, 1, 1/0, or 0
- Selecting Modules for Mirror Images for a RAID 1/0 LUN
- mixed mode
- Bandwidth Mode and Mixed Mode
- setraid5
- number of disk modules
- LUN Binding Order and Restrictions
- Planning the Bind
- rebuilding
- Rebuilding a RAID 5, 3, 1, or 1/0 LUN
- striping
- RAID 1/0 Group: Mirrored RAID 0 Group
- type 3
- RAID 3: Parallel Access Array
- and other LUNs in same array
- Memory Partitioning Points
- and rebooting
- Memory Partitioning Points
- setraid5
- Partitioning Array Memory
- compared with individual disk
- RAID 3: Parallel Access Array
- compared with RAID 0
- RAID 3: Parallel Access Array
- compared with RAID 5
- RAID 3: Parallel Access Array
- hardware requirements
- Hardware Requirements for RAID 3 LUNs
- hot spare limit
- RAID Hot Spare
- Setting Bind Parameters: RAID 3 and Hot Spares
- LUN Integrity and Disk Module Failure
- memory
- Partitioning Array Memory
- memory:and cache
- Memory Partitioning Points
- memory:requirement
- Memory Partitioning Points
- Memory, Bandwidth Mode, and Mixed Mode
- memory:setting
- Partitioning Array Memory
- setcache
- mixed mode
- Bandwidth Mode and Mixed Mode
- mixed mode:setting
- Setting Bind Parameters: RAID 3 and Hot Spares
- setraid5
- Setting Bind Parameters: RAID 3 and Hot Spares
- number of disk modules
- Planning the Bind
- LUN Binding Order and Restrictions
- performance
- Bandwidth Mode and Mixed Mode
- rebuilding
- Rebuilding a RAID 5, 3, 1, or 1/0 LUN
- setting partition
- Partitioning Array Memory
- striping
- bind Syntax
- RAID 3: Parallel Access Array
- unowned if 0 MB memory
- Partitioning Array Memory
- write buffering
- r3wrbuff
- Setting Bind Parameters: RAID 3 and Hot Spares
- type 5
- RAID 5: Individual Access Array
- compared with RAID 3
- RAID 3: Parallel Access Array
- mixed mode
- setraid5
- Bandwidth Mode and Mixed Mode
- number of disk modules
- Planning the Bind
- LUN Binding Order and Restrictions
- rebuilding
- Rebuilding a RAID 5, 3, 1, or 1/0 LUN
- striping
- RAID 5: Individual Access Array
- type, changing
- Changing LUN RAID Type
- raidcli
- subcommands
- ssmcli Subcommands
- summarized
- ssmcli Subcommands
- read cache
- Partitioning Array Memory
- Bind Parameters
- Bind Parameters
- Bind Parameters
- and RAID 3
- Setting Bind Parameters: RAID 3 and Hot Spares
- changing state
- Changing LUN Parameters in the Array Configuration Window
- See also caching.
- Hardware Requirements for Caching: LUNs Other than RAID 3
- setting
- Partitioning Array Memory
- Setting Bind Parameters: RAID 5, 1, 1/0, or 0
- read histogram
- getlun
- read-ahead caching. See prefetch parameters.
- Changing Prefetch (Read-Ahead Caching) Parameters
- rebooting, automatic, with RAID 3 memory reset
- Partitioning Array Memory
- setraid5
- Memory Partitioning Points
- rebootSP
- rebootSP
- rebuild priority
- Bind Parameters
- bind Syntax
- Bind Parameters
- Bind Parameters
- chglun
- changing
- Changing LUN Parameters in the Array Configuration Window
- setting
- Setting Bind Parameters: RAID 5, 1, 1/0, or 0
- Setting Bind Parameters: RAID 3 and Hot Spares
- reestablishing communication with array
- Re-Establishing Communication With an Array
- RS-232 standard
- Origin2000 and Onyx2 Serial Pinout
- scsifo
- Transferring Control of a LUN (Manual Trespass)
- scsiha
- Transferring Control of a LUN (Manual Trespass)
- Making LUNs Available to the Server Operating System
- serial
- cable length
- Origin2000 and Onyx2 Serial Pinout
- connector
- Origin2000 and Onyx2 Serial Pinout
- server hostname
- adding
- Using the Host Administration Window to Add Servers
- removing
- Removing Servers
- setcache
- setcache
- setraid5
- setraid5
- setsniffer
- setsniffer
- setstats
- setstats
- sniff process and reporting
- getsniffer
- setsniffer
- ssmgui Architecture
- setting
- setspstime
- setsniffer
- SP
- Cache information window
- SP Cache Information
- Configuration information window
- Using the SP Information Windows
- default
- chglun
- Bind Parameters
- Bind Parameters
- Setting Bind Parameters: RAID 3 and Hot Spares
- changing
- Changing LUN Parameters in the Array Configuration Window
- event log
- Displaying an SP Event Log
- getlog
- fault
- Faulted SP
- information
- Using the SP Information Windows
- memory
- Partitioning Array Memory
- explained
- Memory and Caching
- rebooting
- rebootSP
- revision level
- and write cache
- Upgrading an Array for Caching
- Hardware Requirements for Caching: LUNs Other than RAID 3
- Cache and Cache Page Size
- determining
- Cache and Cache Page Size
- state
- getcrus
- Statistics information window
- SP Statistics Information
- transferring LUNs
- Transferring Control of a LUN (Manual Trespass)
- SPS
- fault
- Faulted SPS
- self-test
- getcache
- state
- getcrus
- ssmagent
- ssmgui Architecture
- Checking ssmagent Installation
- and RAID GUI
- Starting the RAID GUI
- checking installation
- Checking ssmagent Installation
- polling
- Using ssmagent Polling
- restarting
- Restarting ssmagent
- starting
- Starting the Fibre Channel RAID Agent ssmagent
- stopping
- Starting the Fibre Channel RAID Agent ssmagent
- users and sessions
- ssmagent Users and Sessions
- version
- getagent
- ssmcli
- ssmcli
- error values
- ssmcli Error Values
- subcommands
- ssmcli Subcommands
- syntax
- ssmcli Syntax
- ssmgui
- ssmgui Architecture
- See also RAID GUI.
- Starting the RAID GUI
- statistics logging
- Using Statistics Logging
- setstats
- Storage System Manager window
- features
- Storage System Manager Window
- icon
- Array Health Indicators in the Storage System Manager Window
- toolbar
- Using Storage System Manager Toolbar Buttons
- striping
- Enhanced Performance: Disk Striping
- boundary crossing
- getlun
- count
- bind Syntax
- default size
- Enhanced Performance: Disk Striping
- RAID 0
- RAID 0 Group: Nonredundant Array
- RAID 1/0
- RAID 1/0 Group: Mirrored RAID 0 Group
- RAID 3
- bind Syntax
- RAID 3: Parallel Access Array
- RAID 5
- RAID 5: Individual Access Array
- size
- Bind Parameters
- getlun
- Bind Parameters
- Bind Parameters
- setting
- bind Syntax
- Setting Bind Parameters: RAID 5, 1, 1/0, or 0
- toolbar
- array
- Using Array Toolbar Buttons
- Array Configuration
- Using Array Toolbar Buttons
- LUN
- Reconfiguring and Fine-Tuning
- Storage System Manager
- Using Storage System Manager Toolbar Buttons
- trespass
- trespass
- Transferring Control of a LUN (Manual Trespass)
- Transferring Control of a LUN (Manual Trespass)
- state
- getlun
- unbind
- Unbinding a LUN
- unbind
- unowned LUN
- LUN Integrity and Disk Module Failure
- unsupported array
- Enclosure Health and Accessibility
- user free memory
- Partitioning Array Memory
- Partitioning Array Memory
- verify priority
- Bind Parameters
- bind Syntax
- chglun
- Bind Parameters
- Bind Parameters
- changing
- Changing LUN Parameters in the Array Configuration Window
- setting
- Setting Bind Parameters: RAID 5, 1, 1/0, or 0
- Setting Bind Parameters: RAID 3 and Hot Spares
- watermark
- Changing Write Cache Watermarks
- setcache
- getcache
- getcontrol
- web site for documentation
- Other Documentation
- write cache
- Partitioning Array Memory
- Bind Parameters
- Bind Parameters
- Bind Parameters
- and RAID 3
- Setting Bind Parameters: RAID 3 and Hot Spares
- and SP revision level
- Hardware Requirements for Caching: LUNs Other than RAID 3
- Cache and Cache Page Size
- Upgrading an Array for Caching
- changing state
- Changing LUN Parameters in the Array Configuration Window
- same for both SPs
- Partitioning Array Memory
- See also caching.
- Hardware Requirements for Caching: LUNs Other than RAID 3
- setting
- Partitioning Array Memory
- Setting Bind Parameters: RAID 5, 1, 1/0, or 0
- write histogram
- getlun
Origin FibreVault and Fibre Channel RAID Administrator's Guide
(document number: 007-3715-002 / published: 1998-12-23)
table of contents | additional info | download
Front Matter
About This Guide
Chapter 1. Fibre Channel RAID Graphical User Interface Features
Chapter 2. Using the RAID GUI to Configure Arrays
Chapter 3. Reconfiguring and Fine-Tuning
Chapter 4. Monitoring Arrays and Displaying System Statistics
Chapter 5. Identifying and Correcting Failures
Chapter 6. The Fibre Channel RAID Command-Line Interface
Chapter 7. The Fibre Channel Non-RAID Command-Line Interface
Appendix A. Error Recovery
Appendix B. Server Serial Connector Pinouts
Appendix C. Cache and Cache Page Size
Index
home/search |