SGI Techpubs Library

IRIX 6.5  »  Books  »  Administrative  »  
Origin FibreVault and Fibre Channel RAID Administrator's Guide
(document number: 007-3715-002 / published: 1998-12-23)    table of contents  |  additional info  |  download
find in page

Appendix C. Cache and Cache Page Size

This appendix contains information on read cache and write cache size, cache page size, and storage processor revision level.

The amount of write cache you can allocate depends on the SP revision level. To determine the revision level of an SP, open the door of the storage system and observe the label on the SP panel; see Figure C-1.

Figure C-1. Determining SP Revision Level from SP Label


Another way to determine SP revision level is to enter

scsicontrol -I devicename 

In the output, look for the numerals 00 or 01 at the right, as pointed out in Figure C-2.

Figure C-2. Determining SP Revision Level From scsicontrol -I Output


In this output, 00 corresponds to 9470198 and 01 corresponds to 9470284 (formerly 9470207).

Table C-1 and Table C-2 show the relationships between cache page size and cache configuration for each revision level of SP.

Table C-1. Cache Capability for SP 9470198

Cache Page Size

User-Configurable
Write Cache

User-Configurable
Read Cache

Cache Configuration

2 KB

14 MB
0
7 MB

0
21 MB
7 MB

100% write cache
100% read cache
50% write/50% read

4 KB

28 MB
0
14 MB

0
43 MB
14 MB

100% write cache
100% read cache
50% write/50% read

8 KB

56 MB
0
28 MB

0
86 MB
28 MB

100% write cache
100% read cache
50% write/50% read

16 KB

113 MB
0
56 MB

0
120 MB
56 MB

100% write cache
100% read cache
50% write/50% read


Table C-2. Cache Capability for SP 9470284

Cache Page Size

User-Configurable
Write Cache

User-Configurable
Read Cache

Cache Configuration

2 KB

194 MB
0
106 MB

0
248 MB
106 MB

100% write cache
100% read cache
50% write/50% read

4 KB

388 MB
0
213 MB

0
497 MB
213 MB

100% write cache
100% read cache
50% write/50% read

8 KB

504 MB
0
426 MB

0
504 MB
426 MB

100% write cache
100% read cache
50% write/50% read

16 KB

504 MB
0
504 MB

0
504 MB
504 MB

100% write cache
100% read cache
50% write/50% read


Origin FibreVault and Fibre Channel RAID Administrator's Guide
(document number: 007-3715-002 / published: 1998-12-23)    table of contents  |  additional info  |  download

    Front Matter
    About This Guide
    Chapter 1. Fibre Channel RAID Graphical User Interface Features
    Chapter 2. Using the RAID GUI to Configure Arrays
    Chapter 3. Reconfiguring and Fine-Tuning
    Chapter 4. Monitoring Arrays and Displaying System Statistics
    Chapter 5. Identifying and Correcting Failures
    Chapter 6. The Fibre Channel RAID Command-Line Interface
    Chapter 7. The Fibre Channel Non-RAID Command-Line Interface
    Appendix A. Error Recovery
    Appendix B. Server Serial Connector Pinouts
    Appendix C. Cache and Cache Page Size
    Index


home/search | what's new | help